Back to Search
Start Over
Measurement of the Injection Beam Parameters by the Multi-Wire Scanner for CSNS
- Publication Year :
- 2018
- Publisher :
- JACoW Publishing, Geneva, Switzerland, 2018.
-
Abstract
- In order to inject the H⁻ beam to the Rapid Cycling Synchrotron (RCS) with high precision and high transport efficiency, the injection beam parameters need to be measured and then corrected while its eccentric position or direction angle is too large. In this paper, firstly, a method to measure the injection beam parameters by using two of the four multi-wire scanners (MWSs) is presented. The injection commissioning results confirmed that this method works well. Secondly, a method to measure the signals of injection beam and circular beam by the INMWS02 is presented and the method work well during the beam commissioning.<br />Proceedings of the 9th Int. Particle Accelerator Conf., IPAC2018, Vancouver, BC, Canada
Details
- Language :
- English
- Database :
- OpenAIRE
- Accession number :
- edsair.doi...........745007fb0962f4ef38db18ebad6dd38e
- Full Text :
- https://doi.org/10.18429/jacow-ipac2018-tupal003