Back to Search Start Over

Measured response of bubble neutron detectors and prospects for alpha knock-on diagnostics

Authors :
A. Belian
J. Liptac
E. Morse
R. K. Fisher
C. E. Brient
M. L. Loughlin
A. L. Roquemore
S. S. Medley
Paul Parks
D. C. Ingram
Source :
Review of Scientific Instruments. 72:796-800
Publication Year :
2001
Publisher :
AIP Publishing, 2001.

Abstract

Measurement of the neutron energy spectrum above ∼16 MeV will yield information on the spatial and energy distributions of confined fast alphas in deuterium–tritium (DT) tokamaks (Fisher, Nucl. Fusion; Gorini Rev. Sci. Instrum.). The energetic neutrons result from fusion reactions involving the energetic ions created by alpha-fuel ion knock-on collisions. Standard two-gas bubble neutron detectors, designed to only detect neutrons with energies above a selectable threshold determined by the gas mixture, were used in preliminary attempts to measure the knock-on neutrons from DT plasmas in the Tokamak Fusion Test Reactor and Joint European Torus (JET). Subsequent measurements at accelerator neutron sources showed an unexpected below-threshold detector response that prevented observations of the alpha-induced neutron tails. Spontaneous bubble nucleation measurements show that the majority of this below-threshold response is due to slight variations in the gas mixture, and is not present in single-gas detectors. Single-gas detectors will be tested at the University of California Berkeley to determine the neutron energy threshold as a function of detector operating temperature and to confirm their suitability for alpha knock-on tail measurements. An array of single-gas detectors operating at different temperatures should allow measurements of the alpha knock-on neutron tail during planned DT experiments on JET.Measurement of the neutron energy spectrum above ∼16 MeV will yield information on the spatial and energy distributions of confined fast alphas in deuterium–tritium (DT) tokamaks (Fisher, Nucl. Fusion; Gorini Rev. Sci. Instrum.). The energetic neutrons result from fusion reactions involving the energetic ions created by alpha-fuel ion knock-on collisions. Standard two-gas bubble neutron detectors, designed to only detect neutrons with energies above a selectable threshold determined by the gas mixture, were used in preliminary attempts to measure the knock-on neutrons from DT plasmas in the Tokamak Fusion Test Reactor and Joint European Torus (JET). Subsequent measurements at accelerator neutron sources showed an unexpected below-threshold detector response that prevented observations of the alpha-induced neutron tails. Spontaneous bubble nucleation measurements show that the majority of this below-threshold response is due to slight variations in the gas mixture, and is not present in single-gas detector...

Details

ISSN :
10897623 and 00346748
Volume :
72
Database :
OpenAIRE
Journal :
Review of Scientific Instruments
Accession number :
edsair.doi...........75a62e41d6c2586db6168e1199f603fc
Full Text :
https://doi.org/10.1063/1.1319870