Back to Search
Start Over
Measured response of bubble neutron detectors and prospects for alpha knock-on diagnostics
- Source :
- Review of Scientific Instruments. 72:796-800
- Publication Year :
- 2001
- Publisher :
- AIP Publishing, 2001.
-
Abstract
- Measurement of the neutron energy spectrum above ∼16 MeV will yield information on the spatial and energy distributions of confined fast alphas in deuterium–tritium (DT) tokamaks (Fisher, Nucl. Fusion; Gorini Rev. Sci. Instrum.). The energetic neutrons result from fusion reactions involving the energetic ions created by alpha-fuel ion knock-on collisions. Standard two-gas bubble neutron detectors, designed to only detect neutrons with energies above a selectable threshold determined by the gas mixture, were used in preliminary attempts to measure the knock-on neutrons from DT plasmas in the Tokamak Fusion Test Reactor and Joint European Torus (JET). Subsequent measurements at accelerator neutron sources showed an unexpected below-threshold detector response that prevented observations of the alpha-induced neutron tails. Spontaneous bubble nucleation measurements show that the majority of this below-threshold response is due to slight variations in the gas mixture, and is not present in single-gas detectors. Single-gas detectors will be tested at the University of California Berkeley to determine the neutron energy threshold as a function of detector operating temperature and to confirm their suitability for alpha knock-on tail measurements. An array of single-gas detectors operating at different temperatures should allow measurements of the alpha knock-on neutron tail during planned DT experiments on JET.Measurement of the neutron energy spectrum above ∼16 MeV will yield information on the spatial and energy distributions of confined fast alphas in deuterium–tritium (DT) tokamaks (Fisher, Nucl. Fusion; Gorini Rev. Sci. Instrum.). The energetic neutrons result from fusion reactions involving the energetic ions created by alpha-fuel ion knock-on collisions. Standard two-gas bubble neutron detectors, designed to only detect neutrons with energies above a selectable threshold determined by the gas mixture, were used in preliminary attempts to measure the knock-on neutrons from DT plasmas in the Tokamak Fusion Test Reactor and Joint European Torus (JET). Subsequent measurements at accelerator neutron sources showed an unexpected below-threshold detector response that prevented observations of the alpha-induced neutron tails. Spontaneous bubble nucleation measurements show that the majority of this below-threshold response is due to slight variations in the gas mixture, and is not present in single-gas detector...
- Subjects :
- inorganic chemicals
Physics
Bonner sphere
Neutron emission
Nuclear Theory
technology, industry, and agriculture
Neutron temperature
Nuclear physics
Neutron generator
Physics::Plasma Physics
biological sciences
Neutron cross section
Neutron detection
Neutron source
lipids (amino acids, peptides, and proteins)
Neutron
Nuclear Experiment
Instrumentation
Subjects
Details
- ISSN :
- 10897623 and 00346748
- Volume :
- 72
- Database :
- OpenAIRE
- Journal :
- Review of Scientific Instruments
- Accession number :
- edsair.doi...........75a62e41d6c2586db6168e1199f603fc
- Full Text :
- https://doi.org/10.1063/1.1319870