Back to Search Start Over

An Inter-Turn Short-Circuits Fault Detection Strategy Considering Inverter Nonlinearity and Current Measurement Errors for Sensorless Control of SPMSM

Authors :
Zou Jibin
Yangrui Wang
Yongxiang Xu
Source :
IEEE Transactions on Industrial Electronics. 69:11709-11722
Publication Year :
2022
Publisher :
Institute of Electrical and Electronics Engineers (IEEE), 2022.

Abstract

Aiming at the misdiagnosis problem of the inter-turn short-circuit (ITSC) fault detection method caused by the inverter nonlinearity and the current measurement errors, a d-axis residual voltage-based fault diagnostic strategy is proposed for sensorless control of the surface permanent magnet synchronous motor (SPMSM). The model of the 3-phase wye-connected SPMSM with ITSC fault is established, and the expression of the d-axis residual voltage caused by the ITSC fault, the inverter nonlinearity, the current measurement errors and the motor parameter errors is derived. The proposed fault diagnostic strategy can eliminate the current relative gain coefficient error and locate the ITSC fault by using the 8th and 2nd harmonics of the estimated d-axis residual voltage, respectively. The experimental results verify the effectiveness of the proposed fault diagnostic strategy.

Details

ISSN :
15579948 and 02780046
Volume :
69
Database :
OpenAIRE
Journal :
IEEE Transactions on Industrial Electronics
Accession number :
edsair.doi...........7733c418dfe1ea9e948b3e4d82fdf5af
Full Text :
https://doi.org/10.1109/tie.2021.3125653