Back to Search
Start Over
An Inter-Turn Short-Circuits Fault Detection Strategy Considering Inverter Nonlinearity and Current Measurement Errors for Sensorless Control of SPMSM
- Source :
- IEEE Transactions on Industrial Electronics. 69:11709-11722
- Publication Year :
- 2022
- Publisher :
- Institute of Electrical and Electronics Engineers (IEEE), 2022.
-
Abstract
- Aiming at the misdiagnosis problem of the inter-turn short-circuit (ITSC) fault detection method caused by the inverter nonlinearity and the current measurement errors, a d-axis residual voltage-based fault diagnostic strategy is proposed for sensorless control of the surface permanent magnet synchronous motor (SPMSM). The model of the 3-phase wye-connected SPMSM with ITSC fault is established, and the expression of the d-axis residual voltage caused by the ITSC fault, the inverter nonlinearity, the current measurement errors and the motor parameter errors is derived. The proposed fault diagnostic strategy can eliminate the current relative gain coefficient error and locate the ITSC fault by using the 8th and 2nd harmonics of the estimated d-axis residual voltage, respectively. The experimental results verify the effectiveness of the proposed fault diagnostic strategy.
Details
- ISSN :
- 15579948 and 02780046
- Volume :
- 69
- Database :
- OpenAIRE
- Journal :
- IEEE Transactions on Industrial Electronics
- Accession number :
- edsair.doi...........7733c418dfe1ea9e948b3e4d82fdf5af
- Full Text :
- https://doi.org/10.1109/tie.2021.3125653