Back to Search Start Over

Comparative study of permanent magnet synchronous machine vs salient pole synchronous machine in high temperature application

Authors :
Romain Cousseau
Raphaël Romary
François Balavoine
Miftah Irhoumah
Remus Pusca
Source :
The European Physical Journal Applied Physics. 97:52
Publication Year :
2022
Publisher :
EDP Sciences, 2022.

Abstract

This paper presents the sizing and the comparison of two synchronous machines. The purpose is to design a high temperature dedicated machine with the same performance and volume as a permanent magnet machine. To compare the machines, torque has been chosen as a reference indicator and not the efficiency which will be not so good for the high temperature machine. A salient pole wound rotor is chosen with anodized aluminum tape as windings. Works presented should be considered as preliminary studies leading to the conception of a prototype.

Details

ISSN :
12860050 and 12860042
Volume :
97
Database :
OpenAIRE
Journal :
The European Physical Journal Applied Physics
Accession number :
edsair.doi...........7739e1c8a40985eeeccca75d7788651c
Full Text :
https://doi.org/10.1051/epjap/2022210279