Electromechanical reshaping of ex vivo porcine trachea
- Source :
- The Laryngoscope. 125:1628-1632
- Publication Year :
- 2015
- Publisher :
- Wiley, 2015.
-
Abstract
- Objectives The trachea is a composite cartilaginous structure particularly prone to various forms of convexities. Electromechanical reshaping (EMR) is an emerging technique used to reshape cartilaginous tissues by applying electric current in tandem with imposed mechanical deformation to achieve shape change. In this study, EMR was used to reshape tracheal cartilage rings to demonstrate the feasibility of this technology as a potentially minimally invasive procedure to alter tracheal structure. Study Design Controlled laboratory study using ex vivo porcine tracheae. Methods The natural concavity of each porcine tracheal ring was reversed around a cork mandrel. Two pairs of electrodes were inserted along the long axis of the tracheal ring and placed 1.5 millimeters from the midline. Current was applied over a range of voltages (3 volts [V], 4V, and 5V) for either 2 or 3 minutes. The degree of EMR-induced reshaping was quantified from photographs using digital techniques. Confocal imaging with fluorescent live and dead assays was conducted to determine viability of the tissue after EMR. Results Specimens that underwent EMR for 2 or 3 minutes at 4V or 5V were observed to have undergone significant (P