Back to Search
Start Over
Analytical methods and monitoring system for E-beam flue gas treatment process
- Source :
- Radiation Physics and Chemistry. 52:351-354
- Publication Year :
- 1998
- Publisher :
- Elsevier BV, 1998.
-
Abstract
- The results of reliable and precise measurement of gas composition in different key points of e-beam installation are necessary for its proper operation and control. Only the composition of flue gas coming into installation is adequate to composition of flue gas emitted from coal-fired boiler. At other points of e-b installation the gas composition is strongly modified by process conditions therefore specific measuring system (sampling and conditioning system and set of gas analyzers) for its determination are required. In the paper system for gas composition measurement at inlet and outlet of e-b installation are described. Process parameters are continuously monitoring by CEM system and occasionally by the grab sample system. Both system have been tested at pilot plant at EPS Kawȩczyn.
Details
- ISSN :
- 0969806X
- Volume :
- 52
- Database :
- OpenAIRE
- Journal :
- Radiation Physics and Chemistry
- Accession number :
- edsair.doi...........81b965ee478486a54c5a114dcffa5f1c
- Full Text :
- https://doi.org/10.1016/s0969-806x(98)00032-2