Back to Search Start Over

Analytical methods and monitoring system for E-beam flue gas treatment process

Authors :
Shoji Hashimoto
Grazyna Zakrzewska-Trznadel
Andrzej G. Chmielewski
Janusz Licki
O. Tokunaga
Edward Iller
Source :
Radiation Physics and Chemistry. 52:351-354
Publication Year :
1998
Publisher :
Elsevier BV, 1998.

Abstract

The results of reliable and precise measurement of gas composition in different key points of e-beam installation are necessary for its proper operation and control. Only the composition of flue gas coming into installation is adequate to composition of flue gas emitted from coal-fired boiler. At other points of e-b installation the gas composition is strongly modified by process conditions therefore specific measuring system (sampling and conditioning system and set of gas analyzers) for its determination are required. In the paper system for gas composition measurement at inlet and outlet of e-b installation are described. Process parameters are continuously monitoring by CEM system and occasionally by the grab sample system. Both system have been tested at pilot plant at EPS Kawȩczyn.

Details

ISSN :
0969806X
Volume :
52
Database :
OpenAIRE
Journal :
Radiation Physics and Chemistry
Accession number :
edsair.doi...........81b965ee478486a54c5a114dcffa5f1c
Full Text :
https://doi.org/10.1016/s0969-806x(98)00032-2