Back to Search Start Over

Performance analysis and comparison of FXLMS and FULMS algorithm for active structure vibration control

Authors :
Gao Shouwei
Yi Jincong
Zhu Xiaojin
Gao Zhiyuan
Shao Yong
Source :
2010 2nd International Conference on Advanced Computer Control.
Publication Year :
2010
Publisher :
IEEE, 2010.

Abstract

Taking the piezoelectric beam as research object, filtered-U least mean square (FULMS) control algorithm for feed-forward adaptive control is analyzed and compared with filtered-x least mean square (FXLMS) feed-forward control algorithm, which can solve the problem that the vibration feedback may affect the measuring of the reference signal in FXLMS. By introducing FXLMS and FULMS control algorithm, this paper gives the controller design structure, while structure modal analysis to determine the optimal placement of piezoelectric sensors and actuators and model parameter identification for the controlled structure are done. Then the active vibration control experimental platform is established to verify the effectiveness of FULMS control scheme as well as FXLMS control scheme. Meanwhile the experimental results of FXLMS and FULMS are compared. The performance comparison shows that the FULMS adaptive vibration controller has a better control performance, with more rapid convergence than FXLMS controller.

Details

Database :
OpenAIRE
Journal :
2010 2nd International Conference on Advanced Computer Control
Accession number :
edsair.doi...........84b82bdc77f47adbad16093be0f086a2