Back to Search
Start Over
Radiation in the C0 assembly hall due to muons from accidental beam loss in the Tevatron
- Publication Year :
- 2005
- Publisher :
- Office of Scientific and Technical Information (OSTI), 2005.
-
Abstract
- A set of calculations performed with the MARS15 code indicates a maximum radiation dose due to muons in the C0 Assembly Building (C0 AB) for a person standing on a ladder in the orbit plane of the Tevatron of 10 mrem and a maximum dose for a person standing on a C0 AB floor < 1 mrem per loss of 2.5 x 10{sup 13} protons of 1 TeV energy in the Tevatron.
Details
- Database :
- OpenAIRE
- Accession number :
- edsair.doi...........8f515881ffe97eb2e033bda4ed480948
- Full Text :
- https://doi.org/10.2172/15020255