Back to Search Start Over

Load Disturbance Compensation for Stand-alone Inverters Using an Inductor Current Observer

Authors :
Seung-Ryul Moon
Byeng-Joo Byen
Gyu-Ha Choe
Jung-Muk Choe
Young-Bae Lim
Jih-Sheng Lai
Source :
Journal of Power Electronics. 17:389-397
Publication Year :
2017
Publisher :
The Korean Institute of Power Electronics, 2017.

Abstract

A control scheme for stand-alone inverters that utilizes an inductor current observer (ICO) is proposed. The proposed method measures disturbance load currents using a current sensor and it estimates the inductor current using the ICO. The filter parameter mismatch effect is analyzed to confirm the ICO’s controllability. The ICO and controllers are designed in a continuous-time domain and transferred to a discrete-time domain with a digital delay. Experimental results demonstrate the effectiveness of the ICO using a 5-kVA single-phase stand-alone inverter prototype. The experimental results demonstrate that the observed current matches the actual current and that the proposed method can archive a less than 2.4% total harmonic distortion (THD) sinusoidal output waveform under nonlinear load conditions.

Details

ISSN :
15982092
Volume :
17
Database :
OpenAIRE
Journal :
Journal of Power Electronics
Accession number :
edsair.doi...........90b502fc769a3a3846658d02736cfaa0