Back to Search
Start Over
Load Disturbance Compensation for Stand-alone Inverters Using an Inductor Current Observer
- Source :
- Journal of Power Electronics. 17:389-397
- Publication Year :
- 2017
- Publisher :
- The Korean Institute of Power Electronics, 2017.
-
Abstract
- A control scheme for stand-alone inverters that utilizes an inductor current observer (ICO) is proposed. The proposed method measures disturbance load currents using a current sensor and it estimates the inductor current using the ICO. The filter parameter mismatch effect is analyzed to confirm the ICO’s controllability. The ICO and controllers are designed in a continuous-time domain and transferred to a discrete-time domain with a digital delay. Experimental results demonstrate the effectiveness of the ICO using a 5-kVA single-phase stand-alone inverter prototype. The experimental results demonstrate that the observed current matches the actual current and that the proposed method can archive a less than 2.4% total harmonic distortion (THD) sinusoidal output waveform under nonlinear load conditions.
- Subjects :
- Total harmonic distortion
Engineering
Observer (quantum physics)
business.industry
020208 electrical & electronic engineering
020302 automobile design & engineering
02 engineering and technology
Inductor
Controllability
0203 mechanical engineering
Control and Systems Engineering
Control theory
Delay
0202 electrical engineering, electronic engineering, information engineering
Electronic engineering