Back to Search
Start Over
Left atrial appendage occlusion using a Watchman device in a transplanted heart with biatrial anastomosis
- Source :
- Catheterization and Cardiovascular Interventions. 93:758-760
- Publication Year :
- 2018
- Publisher :
- Wiley, 2018.
-
Abstract
- A percutaneous left atrial appendage (LAA) occlusion using a Watchman device was performed in a patient with prior biatrial anastomosis orthotopic heart transplant (OHT). Due to the anatomical changes following biatrial anastomosis, transesophageal echocardiography (TEE) imaging and transseptal puncture become technically challenging. We describe how the standard LAA views on TEE were obtained for device sizing, and how the transseptal puncture was modified to cross the scarred septum. This case demonstrates that LAA occlusion using a Watchman device in biatrial anastomosis OHT is safe and can successfully be done.
- Subjects :
- medicine.medical_specialty
Percutaneous
business.industry
medicine.medical_treatment
Transplanted heart
General Medicine
030204 cardiovascular system & hematology
Anastomosis
Left atrial appendage occlusion
Surgery
03 medical and health sciences
0302 clinical medicine
Left atrial
Occlusion
medicine
Radiology, Nuclear Medicine and imaging
030212 general & internal medicine
Cardiology and Cardiovascular Medicine
business
Subjects
Details
- ISSN :
- 1522726X and 15221946
- Volume :
- 93
- Database :
- OpenAIRE
- Journal :
- Catheterization and Cardiovascular Interventions
- Accession number :
- edsair.doi...........916238228c75f5bedb0d7a77aac471c2
- Full Text :
- https://doi.org/10.1002/ccd.28027