Back to Search Start Over

Unbalanced Magnetic Forces in Permanent-Magnet Brushless Machines With Diametrically Asymmetric Phase Windings

Authors :
Zi-Qiang Zhu
Dahaman Ishak
David Howe
Chen Jintao
Source :
IEEE Transactions on Industry Applications. 43:1544-1553
Publication Year :
2007
Publisher :
Institute of Electrical and Electronics Engineers (IEEE), 2007.

Abstract

A general analytical model, formulated in 2-D polar coordinates, is developed to predict the unbalanced magnetic force, which results in permanent-magnet brushless ac and dc machines having a diametrically asymmetric disposition of slots and phase windings. It is shown that the unbalanced magnetic force can be significant in machines having a fractional ratio of slot number to pole number, particularly when the electric loading is high. The developed model is validated by finite-element calculations on 9-slot/8-pole and 3-slot/2-pole machines. In addition, the unbalanced magnetic force has been measured on a prototype 3-slot/2-pole machine and shown to be in excellent agreement with predicted results.

Details

ISSN :
00939994
Volume :
43
Database :
OpenAIRE
Journal :
IEEE Transactions on Industry Applications
Accession number :
edsair.doi...........926e810e159dfc7856e0b88ad1afd51f
Full Text :
https://doi.org/10.1109/tia.2007.908158