Determination of Uric Acid in the Presence of Ascorbic Acid Using Poly(3,4-ethylenedioxythiophene)-Modified Electrodes

Authors :
Jayaraman Mathiyarasu
Yogendra Kumar Jain
Shanmugam Senthil Kumar
V. Yegnaraman
Kanala Lakshminarasimha Phani
Source :
Electroanalysis. 17:2281-2286
Publication Year :
2005
Publisher :
Wiley, 2005.

Abstract

A poly(3,4-ethylenedioxythiophene) (PEDOT) modified glassy carbon electrode (GCE) was used to determine uric acid in the presence of ascorbic acid at physiological pH facilitating a peak potential separation of ascorbic acid and uric acid oxidation (ca. 365 mV), which is the largest value reported so far in the literature. Also, an analytical protocol involving differential pulse voltammetry has been developed using a microchip electrode for the determination of uric acid in the concentration range of 1 to 20 mM in presence of excess of ascorbic acid.