Back to Search Start Over

High heat flux test of tungsten brazed mock-ups developed for KSTAR divertor

Authors :
Dong Won Lee
Kyungmin Kim
H.T. Kim
Hee-Jae Ahn
Hyeon K. Park
Sungkyu Kim
Soo-Hwan Park
S.H. Hong
JaeIn Song
Source :
Fusion Engineering and Design. :78-81
Publication Year :
2016
Publisher :
Elsevier BV, 2016.

Abstract

The tungsten (W) brazed flat type mock-up which consists of W, OFHC-Cu (oxygen-free high conductive copper) and CuCrZr alloy has been designed for KSTAR divertor in preparation for KSTAR upgrade with 17 MW heating power. For verification of the W brazed mock-up, the high heat flux test is performed at KoHLT-EB (Korea High Heat Load Test Facility-Electron Beam) in KAERI (Korea Atomic Energy Research Institute). Three mock-ups are tested for several thousand thermal cycles with absorbed heat flux up to 5 MW/m 2 for 20 s duration. There is no evidence of the failure at the bonding joints of all mock-ups after HHF test. Finite element analysis (FEA) is performed to interpret the result of the test. As a result, it is considered that the local area in the water is in the subcooled boiling regime.