Benchmarking of scaling and fouling of reverse osmosis membranes in a power generation plant of paper and board mill: an industrial case of a paper and board mill study
- Source :
- International Journal of Environmental Science and Technology. 18:2511-2518
- Publication Year :
- 2020
- Publisher :
- Springer Science and Business Media LLC, 2020.
-
Abstract
- The present study reports the characterization of reverse osmosis (RO) technology at water treatment plant Cogen-2 in paper and Board mills, Pakistan. RO is a commonly used process to obtain de-mineralized water for high-pressure boiler operation in thermal power plants. Scaling and fouling in three-stage RO plants is a major challenge in chemical industry due to the use of raw brackish water in the power plant of paper and board mills. In our study, the feed water quality of RO was changed from soft water to raw water to make it economical. The cleaning frequency was increased three times than normal, which was unsafe for operation and it was required to control scaling and fouling to achieve the desired result. Differential pressures behavior of all stages for 2-month data was observed without acid treatment, and the results of Langelier Saturation Index (LSI) control parameters (temperature, pH, total dissolved solids, calcium hardness, and alkalinity) clearly showed the abnormality. To optimize scaling and fouling of RO, the LSI factor was controlled in total reject water for the next 2 months by acid treatment in feed water. Duration of chemical cleaning and membranes’ life has been extended by fouling and scaling control. Understanding the effect of operational parameters in RO membranes is essential in water process engineering due to its broad applications in drinking water, sanitation, seawater, desalination process, wastewater treatment, and boiler feed water operation. The product flow increased from 18.3 to 19.9 m3/h, and this was due to a decrease in the rejection flow from 8.2 to 6.7 m3/h. The total reject stream pressure also increased from 8.1 to 9 bar. A lower value of LSI of 1.6 is obtained in the reject water stream after the acid treatment.
- Subjects :
- Environmental Engineering
Fouling
Boiler feedwater
Thermal power station
02 engineering and technology
021001 nanoscience & nanotechnology
Pulp and paper industry
Desalination
020401 chemical engineering
Environmental Chemistry
Environmental science
Water treatment
Water quality
0204 chemical engineering
Raw water
0210 nano-technology
General Agricultural and Biological Sciences
Reverse osmosis
Subjects
Details
- ISSN :
- 17352630 and 17351472
- Volume :
- 18
- Database :
- OpenAIRE
- Journal :
- International Journal of Environmental Science and Technology
- Accession number :
- edsair.doi...........96384fb1e707623cd97cff3092ab6a46