Back to Search Start Over

Long-Term Outcomes of Brugada Substrate Ablation: A Report from BRAVO (Brugada Ablation of VF Substrate Ongoing Multicenter Registry)

Authors :
Koonlawee Nademanee
Fa-Po Chung
Frederic Sacher
Akihiko Nogami
Hiroshi Nakagawa
Chenyang Jiang
Meleze Hocini
Elijah Behr
Gumpanart Veerakul
Jaap Jan Smit
Arthur A.M. Wilde
Shih-Ann Chen
Kohei Yamashiro
Yuichiro Sakamoto
Itsuro Morishima
Mithilesh K. Das
Apichai Khongphatthanayothin
Saran Vardhanabhuti
Michel Haissaguerre
Source :
Circulation. 147:1568-1578
Publication Year :
2023
Publisher :
Ovid Technologies (Wolters Kluwer Health), 2023.

Abstract

Background: Treatment options for high-risk Brugada syndrome (BrS) with recurrent ventricular fibrillation (VF) are limited. Catheter ablation is increasingly performed but a large study with long-term outcome data is lacking. We report the results of the multicenter, international BRAVO (Brugada Ablation of VF Substrate Ongoing Registry) for treatment of high-risk symptomatic BrS. Methods: We enrolled 159 patients (median age 42 years; 156 male) with BrS and spontaneous VF in BRAVO; 43 (27%) of them had BrS and early repolarization pattern. All but 5 had an implantable cardioverter-defibrillator for cardiac arrest (n=125) or syncope (n=34). A total of 140 (88%) had experienced numerous implantable cardioverter-defibrillator shocks for spontaneous VF before ablation. All patients underwent a percutaneous epicardial substrate ablation with electroanatomical mapping except for 8 who underwent open-thoracotomy ablation. Results: In all patients, VF/BrS substrates were recorded in the epicardial surface of the right ventricular outflow tract; 45 (29%) patients also had an arrhythmic substrate in the inferior right ventricular epicardium and 3 in the posterior left ventricular epicardium. After a single ablation procedure, 128 of 159 (81%) patients remained free of VF recurrence; this number increased to 153 (96%) after a repeated procedure (mean 1.2±0.5 procedures; median=1), with a mean follow-up period of 48±29 months from the last ablation. VF burden and frequency of shocks decreased significantly from 1.1±2.1 per month before ablation to 0.003±0.14 per month after the last ablation ( P P =0.0274). There were no arrhythmic or cardiac deaths. Complications included hemopericardium in 4 (2.5%) patients. Conclusions: Ablation treatment is safe and highly effective in preventing VF recurrence in high-risk BrS. Prospective studies are needed to determine whether it can be an alternative treatment to implantable cardioverter-defibrillator implantation for selected patients with BrS. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT04420078.

Details

ISSN :
15244539 and 00097322
Volume :
147
Database :
OpenAIRE
Journal :
Circulation
Accession number :
edsair.doi...........9864804c8381f5534f7da2c2f6a5ebfd
Full Text :
https://doi.org/10.1161/circulationaha.122.063367