Stellenwert der 20-MHz-Sonographie des malignen Melanoms und pigmentierter Läsionen in der Routinediagnostik

Authors :
Markus Stücker
N. Brautzsch
Strahler J
J. Bohmeyer
S. Schüller
J. Welzel
M. Freitag
Klaus Hoffmann
H. Neubauer
P. Gottlöber
M. Schwarz
J. Wohlrab
M. Wiesner
S. Petereit
Peter Altmeyer
M. Happe
C. Jung
Source :
Ultraschall in der Medizin. 20:104-109
Publication Year :
1999
Publisher :
Georg Thieme Verlag KG, 1999.

Abstract

PURPOSE Eleven dermatology clinics from all over Germany took part in our multicenter prospective study with the aim of evaluating 20 MHz sonography in the preoperative diagnosis of malignant melanomas and other pigmented skin tumours. It was to be assessed how effective sonographic measurement of thickness would compare to histology and the clinical palpation of tumour thickness and also the significance of differential diagnosis in sonography of malignant melanomas. METHOD The prospective multicenter study proceed as follows. To the end of August 1997 264 patients with a primary malignant melanoma and 417 patients with benign skin tumours were examined via 20 MHz sonography. Two different examiners estimated the clinical thickness of the tumour by palpation. The tumour was then excised and examined for postoperative correlation with the histology sections. RESULTS The final results showed good correlation between the histological and sonographic estimation of tumour thickness (r = 0.97). Estimation of tumour thickness by palpation showed no correlation with the histology (r = 0.59). Most of the benign (44%) and malignant tumours (38.7%) were spindle shaped. There was no significant difference between the benign and malignant tumour groups in relation to the sonographic presented shapes or echo signs. No different diagnosis could be made. CONCLUSION The technique of high frequency sonography in relation to preoperative diagnosis of malignant melanomas has high priority. In contrast to clinical estimation of tumour thickness, sonography provided a good correlation to histology. The effectiveness of sonography with regard to the valence of the skin tumours is limited and there is no possibility of differentiating between malignant and benign tumours from the morphological face value. Hence, there is a demand for developing a 150 MHz apparatus which will be able to supply evidence regarding the valence of skin tumours.

Details

ISSN :
14388782 and 01724614
Volume :
20
Database :
OpenAIRE
Journal :
Ultraschall in der Medizin
Accession number :
edsair.doi...........9d026283d9e5b903227fb495c9fed0eb