Developing an edge-plasma diagnostic tool for the Globus-M tokamak based on measuring ratios of HeI lines
- Source :
- Technical Physics Letters. 42:775-778
- Publication Year :
- 2016
- Publisher :
- Pleiades Publishing Ltd, 2016.
-
Abstract
- A diagnostic technique that is based on measuring the ratios of neutral-helium line strengths has been developed for peripheral distributions of electron temperature and density of tokamak plasma. The main components of the technique are a four-channel filter-lens imaging polychromator (FLIP-4) and a Phantom Miro M110 high-speed camera for recording the images. The polychromator has been assembled, adjusted, and tested on an optical test bench. The optical system was installed on the spherical Globus-M tokamak. Some preliminary experiments were carried out. Images of the plasma-gun jet were obtained at neutralhelium lines.
- Subjects :
- 010302 applied physics
Jet (fluid)
Materials science
Tokamak
Physics and Astronomy (miscellaneous)
business.industry
Plasma
Edge (geometry)
01 natural sciences
Imaging phantom
010305 fluids & plasmas
law.invention
Polychromator
Optics
law
0103 physical sciences
Line (geometry)
Electron temperature
business
Subjects
Details
- ISSN :
- 10906533 and 10637850
- Volume :
- 42
- Database :
- OpenAIRE
- Journal :
- Technical Physics Letters
- Accession number :
- edsair.doi...........a2c11837462f1ef0ad4b694c737f20dc
- Full Text :
- https://doi.org/10.1134/s1063785016080162