Back to Search Start Over

Maintenance Factor in Installation of Tunnel Lighting

Authors :
Shoetsu Sakamoto
Satoshi Hirakawa
Tsuyoshi Sugawara
Kunio Toeda
Source :
JOURNAL OF THE ILLUMINATING ENGINEERING INSTITUTE OF JAPAN. 96:69-74
Publication Year :
2012
Publisher :
Illuminating Engineering Society of Japan, 2012.

Abstract

Maintenance factors in installation of tunnel lighting have been considerd in terms of traffic volume and tunnel length based on results from investigations into the use of tunnels. Ventilation conditions in tunnels are drastically improved by reinforcing exhaust gas regulations for cars, and dirt on luminaire is also remarkably reduced. Further, the life times of light sources are advancing. Therefore, we studied lumen maintenance factor, survival factor and partial maintenance factor by using dirty luminaire to take maintenance factor into consideration and these suggested a new method of establishing maintenance factor.

Details

ISSN :
21851506 and 00192341
Volume :
96
Database :
OpenAIRE
Journal :
JOURNAL OF THE ILLUMINATING ENGINEERING INSTITUTE OF JAPAN
Accession number :
edsair.doi...........aa7cdb4bff48171fd77d876e47b99b9b
Full Text :
https://doi.org/10.2150/jieij.96.69