Back to Search Start Over

Effect of incubation temperature on the diagnostic sensitivity of the glanders complement fixation test

Authors :
Iahtasham Khan
Vania Lucia de Assis Santana
Heinrich Neubauer
Falk Melzer
Lothar H. Wieler
Muhammad Saqib
Mandy C. Elschner
Source :
Revue Scientifique et Technique de l'OIE. 33:869-875
Publication Year :
2014
Publisher :
O.I.E (World Organisation for Animal Health), 2014.

Abstract

The complement fixation test (CFT) is the only serological test prescribed by the World Organisation for Animal Health (OIE) for the diagnosis of glanders in international trading of equids. However, false-positive reactions have caused financial losses to the animal owners in the past, and false-negative tests have resulted in the introduction of glanders into healthy equine populations in previously glanders-free areas. Both warm (incubation at 37°C for 1 h) and cold (overnight incubation at 4°C) procedures are recommended by the OIE for serodiagnosis of glanders. In a comparison of the sensitivity and specificity of the two techniques, using the United States Department of Agriculture antigen, warm CFT was found to be significantly less sensitive (56.8%; p < 0.0005) than the cold CFT (83.6%). Cold CFT thus increases the detection rate of glanders but a lower diagnostic specificity has to be accepted. The immunoblot was used as the gold standard.

Details

ISSN :
02531933
Volume :
33
Database :
OpenAIRE
Journal :
Revue Scientifique et Technique de l'OIE
Accession number :
edsair.doi...........ab6cdb3a08b56c2afa32981bedf380e8
Full Text :
https://doi.org/10.20506/rst.33.3.2324