Back to Search
Start Over
Validation of the automated method VIENA: An accurate, precise, and robust measure of ventricular enlargement
- Source :
- Human Brain Mapping. 35:1101-1110
- Publication Year :
- 2013
- Publisher :
- Wiley, 2013.
-
Abstract
- Background: In many retrospective studies and large clinical trials, high-resolution, good-contrast 3DT1 images are unavailable, hampering detailed analysis of brain atrophy. Ventricular enlargement then provides a sensitive indirect measure of ongoing central brain atrophy. Validated automated methods are required that can reliably measure ventricular enlargement and are robust across magnetic resonance (MR) image types. Aim: To validate the automated method VIENA for measuring the percentage ventricular volume change (PVVC) between two scans. Materials and Methods: Accuracy was assessed using four image types, acquired in 15 elderly patients (five with Alzheimer's disease, five with mild cognitive impairment, and five cognitively normal elderly) and 58 patients with multiple sclerosis (MS), by comparing PVVC values from VIENA to manual outlining. Precision was assessed from data with three imaging time points per MS patient, by measuring the difference between the direct (one-step) and indirect (two-step) measurement of ventricular volume change between the first and last time points. The stringent concordance correlation coefficient (CCC) was used to quantify absolute agreement. Results: CCC of VIENA with manual measurement was 0.84, indicating good absolute agreement. The median absolute difference between two-step and one-step measurement with VIENA was 1.01%, while CCC was 0.98. Neither initial ventricular volume nor ventricular volume change affected performance of the method. Discussion: VIENA has good accuracy and good precision across four image types. VIENA therefore provides a useful fully automated method for measuring ventricular volume change in large datasets. Conclusion: VIENA is a robust, accurate, and precise method for measuring ventricular volume change. Hum Brain Mapp 35:1101–1110, 2014. © 2013 Wiley Periodicals, Inc.
- Subjects :
- medicine.medical_specialty
Measure (data warehouse)
Radiological and Ultrasound Technology
medicine.diagnostic_test
business.industry
Magnetic resonance imaging
Absolute difference
Surgery
Concordance correlation coefficient
Neurology
Ventricular enlargement
medicine
Ventricular volume
Radiology, Nuclear Medicine and imaging
Neurology (clinical)
Anatomy
Nuclear medicine
business
Psychology
Cognitive impairment
Automated method
Subjects
Details
- ISSN :
- 10659471
- Volume :
- 35
- Database :
- OpenAIRE
- Journal :
- Human Brain Mapping
- Accession number :
- edsair.doi...........ad733c7eeb998550cc00bcdb97b45afe
- Full Text :
- https://doi.org/10.1002/hbm.22237