Abstract

Advanced research equipment like the SOLARIS synchrotron requires specific working conditions. One of the major disturbances are vibrations of the synchrotron foundation plate, derived from internal equipment and external sources. The purpose of the present research was to identify the dominant sources and to analyze the wave propagation path. In basic research, a set of circulating pumps for cooling liquid was selected and under controlled conditions measurements were made. As a result of the analysis of the data obtained, was revealed an inability to which could affect the work of the synchrotron. The paper presents partial results and conclusions from the research conducted.