Back to Search Start Over

Failure analysis of a titanium Coriolis mass flow meter: A case of hydrogen embrittlement

Authors :
Danielle Cristina Camilo Magalhães
G.S. Vacchi
I.G.R. Santos
Cristie Luis Kugelmeier
Carlos Alberto Della Rovere
R. Silva
G.R. Campesan
Source :
Engineering Failure Analysis. 115:104618
Publication Year :
2020
Publisher :
Elsevier BV, 2020.

Abstract

Titanium alloys are suitable for construction of the Coriolis mass flow meter due to their high strength to weight ratio, high thermal stability and excellent corrosion resistance. However, environments with high hydrogen content can be very harmful to titanium and its alloys, since this element may cause hydride formation and leads to hydrogen embrittlement. In this context, this paper reports on the analysis of a grade 9 titanium tube of a mass flow meter, which was performed using cyclohexanol (68%), water (2%) and Raney nickel catalyst (30%). After the active period, the flow meter was deactivated and left on standby for one year, and then reassembled on a production line, whereupon it failed prematurely. The failure was analyzed by OM, SEM, EDS, Vickers microhardness and XRD, whose results indicated that the cause was hydride embrittlement due to the chemical interaction between Raney nickel and the titanium tube during the deactivated period.

Details

ISSN :
13506307
Volume :
115
Database :
OpenAIRE
Journal :
Engineering Failure Analysis
Accession number :
edsair.doi...........b457e692b9f7079815e1f62e443c1605
Full Text :
https://doi.org/10.1016/j.engfailanal.2020.104618