Back to Search
Start Over
Failure analysis of a titanium Coriolis mass flow meter: A case of hydrogen embrittlement
- Source :
- Engineering Failure Analysis. 115:104618
- Publication Year :
- 2020
- Publisher :
- Elsevier BV, 2020.
-
Abstract
- Titanium alloys are suitable for construction of the Coriolis mass flow meter due to their high strength to weight ratio, high thermal stability and excellent corrosion resistance. However, environments with high hydrogen content can be very harmful to titanium and its alloys, since this element may cause hydride formation and leads to hydrogen embrittlement. In this context, this paper reports on the analysis of a grade 9 titanium tube of a mass flow meter, which was performed using cyclohexanol (68%), water (2%) and Raney nickel catalyst (30%). After the active period, the flow meter was deactivated and left on standby for one year, and then reassembled on a production line, whereupon it failed prematurely. The failure was analyzed by OM, SEM, EDS, Vickers microhardness and XRD, whose results indicated that the cause was hydride embrittlement due to the chemical interaction between Raney nickel and the titanium tube during the deactivated period.
- Subjects :
- Materials science
Hydrogen
Mass flow meter
Hydride
Metallurgy
General Engineering
Titanium alloy
chemistry.chemical_element
020101 civil engineering
02 engineering and technology
Flow measurement
0201 civil engineering
020303 mechanical engineering & transports
0203 mechanical engineering
chemistry
General Materials Science
Embrittlement
Hydrogen embrittlement
Titanium
Subjects
Details
- ISSN :
- 13506307
- Volume :
- 115
- Database :
- OpenAIRE
- Journal :
- Engineering Failure Analysis
- Accession number :
- edsair.doi...........b457e692b9f7079815e1f62e443c1605
- Full Text :
- https://doi.org/10.1016/j.engfailanal.2020.104618