Back to Search Start Over

Device for estimating the strengths of cemented joints in polymer materials

Authors :
K. K. Moroz
A. S. Sabaev
T. A. Sabaeva
Source :
Measurement Techniques. 29:24-25
Publication Year :
1986
Publisher :
Springer Science and Business Media LLC, 1986.

Abstract

Vacuum mounts are used [i] to reduce the time consumed by auxiliary operations in preparing specimens for adhesion-strength test. A disadvantage of some designs of these is that there are large errors of measurement due to the use of slow mechanical devices for recording the failure force. Also, these instruments do not allow one to identify the initial phase, i.e., the load at which cracks are produced. Identifying such defects is very important in tests for example on joint sealing. We have proposed a device for examining adhesion strength in which these deficiencies are eliminated [2].

Details

ISSN :
15738906 and 05431972
Volume :
29
Database :
OpenAIRE
Journal :
Measurement Techniques
Accession number :
edsair.doi...........b92b3a558d8bc8299ea9c0e5f065d7e6
Full Text :
https://doi.org/10.1007/bf00862472