Back to Search
Start Over
The comparison of the enhanced integration-type E&S model and the improved dynamic E&S model of electrical steel sheet under DC-biased magnetizing condition
- Source :
- International Journal of Applied Electromagnetics and Mechanics. 65:171-179
- Publication Year :
- 2021
- Publisher :
- IOS Press, 2021.
-
Abstract
- This paper enhanced the integration-type E&S model and the dynamic E&S model for integrating the impact of DC-biased field and eddy current on vector magnetic properties of electrical steel sheet. B and H of electrical steel sheet are measured under DC-biased and rotating fields. Based on the measured results, the databases of reluctivity and hysteresis coefficients of both the enhanced integration-type E&S model and the improved dynamic E&S model are established for predicting H waveform under any given operating condition. By comparing the H waveform calculated by the enhanced integration-type E&S model and the improved dynamic E&S model with the experimental H waveform, it is found that both two models have good reliability and the improved dynamic E&S model has slightly better accuracy than the enhanced integration-type E&S model.
Details
- ISSN :
- 18758800 and 13835416
- Volume :
- 65
- Database :
- OpenAIRE
- Journal :
- International Journal of Applied Electromagnetics and Mechanics
- Accession number :
- edsair.doi...........ba8c48a424777a1239e35b232584a5d3
- Full Text :
- https://doi.org/10.3233/jae-190095