Back to Search Start Over

Feasibility of mapping and ablating ectopy-triggering ganglionated plexus reproducibly in persistent atrial fibrillation

Authors :
Clare Coyle
Simos Koutsoftidis
Min-Young Kim
Bradley Porter
Daniel Keene
Vishal Luther
Balvinder Handa
Jamie Kay
Elaine Lim
Louisa Malcolme-Lawes
Michael Koa-Wing
Phang Boon Lim
Zachary I. Whinnett
Fu Siong Ng
Norman Qureshi
Nicholas S. Peters
Nicholas W. F. Linton
Emmanuel Drakakis
Prapa Kanagaratnam
Source :
Journal of Interventional Cardiac Electrophysiology.
Publication Year :
2023
Publisher :
Springer Science and Business Media LLC, 2023.

Abstract

Background Ablation of autonomic ectopy-triggering ganglionated plexuses (ET-GP) has been used to treat paroxysmal atrial fibrillation (AF). It is not known if ET-GP localisation is reproducible between different stimulators or whether ET-GP can be mapped and ablated in persistent AF. We tested the reproducibility of the left atrial ET-GP location using different high-frequency high-output stimulators in AF. In addition, we tested the feasibility of identifying ET-GP locations in persistent atrial fibrillation. Methods Nine patients undergoing clinically-indicated paroxysmal AF ablation received pacing-synchronised high-frequency stimulation (HFS), delivered in SR during the left atrial refractory period, to compare ET-GP localisation between a custom-built current-controlled stimulator (Tau20) and a voltage-controlled stimulator (Grass S88, SIU5). Two patients with persistent AF underwent cardioversion, left atrial ET-GP mapping with the Tau20 and ablation (Precision™, Tacticath™ [n = 1] or Carto™, SmartTouch™ [n = 1]). Pulmonary vein isolation (PVI) was not performed. Efficacy of ablation at ET-GP sites alone without PVI was assessed at 1 year. Results The mean output to identify ET-GP was 34 mA (n = 5). Reproducibility of response to synchronised HFS was 100% (Tau20 vs Grass S88; [n = 16] [kappa = 1, SE = 0.00, 95% CI 1 to 1)][Tau20 v Tau20; [n = 13] [kappa = 1, SE = 0, 95% CI 1 to 1]). Two patients with persistent AF had 10 and 7 ET-GP sites identified requiring 6 and 3 min of radiofrequency ablation respectively to abolish ET-GP response. Both patients were free from AF for > 365 days without anti-arrhythmics. Conclusions ET-GP sites are identified at the same location by different stimulators. ET-GP ablation alone was able to prevent AF recurrence in persistent AF, and further studies would be warranted.

Details

ISSN :
15728595
Database :
OpenAIRE
Journal :
Journal of Interventional Cardiac Electrophysiology
Accession number :
edsair.doi...........bb4a8996d79ad2de2ff7edc26441c413