- OBJECTIVE The aim of this in-vitro study was to investigate the tactile assessment ability at the implant impression-taking stage. METHODS Thirty clinicians (18 novices, 12 experts) were included for a tactile fit assessment by using a used/new probe (tip diameter 100 µm/20 µm). Six implant replicas and related impression copings of two internal connection implant systems were used, each with a perfect fit (0 µm) and defined vertical micro gaps of 8, 24, 55, 110 and 220 µm at the interface. Statistical analysis was performed using descriptive methods and non-parametric tests with a focus on specificity (ability to detect perfect fit), sensitivity (ability to detect misfit), and predictive values. P-values