Back to Search Start Over

Two-stage numerical simulation for temperature profile in furnace of tangentially fired pulverized coal boiler

Authors :
Zhou Ping
Zhou Nai-jun
Xu Qiong-hui
Source :
Journal of Central South University of Technology. 12:97-101
Publication Year :
2005
Publisher :
Springer Science and Business Media LLC, 2005.

Abstract

Considering the fact that the temperature distribution in furnace of a tangential fired pulverized coal boiler is difficult to be measured and monitored, two-stage numerical simulation method was put forward. First, multifield coupling simulation in typical work conditions was carried out off-line with the software CFX-4.3, and then the expression of temperature profile varying with operating parameter was obtained. According to real-time operating parameters, the temperature at arbitrary point of the furnace can be calculated by using this expression. Thus the temperature profile can be shown on-line and monitoring for combustion state in the furnace is realized. The simulation model was checked by the parameters measured in an operating boiler, DG130-9.8/540. The maximum of relative error is less than 12% and the absolute error is less than 120 °C, which shows that the proposed two-stage simulation method is reliable and able to satisfy the requirement of industrial application.

Details

ISSN :
19930666 and 10059784
Volume :
12
Database :
OpenAIRE
Journal :
Journal of Central South University of Technology
Accession number :
edsair.doi...........c117da183c3660dc581a707768480f20