Back to Search Start Over

Family of Splitting Current Single-Loop Control for LCL- Type Grid-Connected Inverter

Authors :
Yuying He
Fuxin Liu
Xinbo Ruan
Xuehua Wang
Guoxing Su
Source :
2020 22nd European Conference on Power Electronics and Applications (EPE'20 ECCE Europe).
Publication Year :
2020
Publisher :
IEEE, 2020.

Abstract

The single-loop weighted average current (WAC) control is attractive for the LCL-type grid-connected inverter owing to its inherent active damping. High robustness can be naturally harvested without any additional damping methods, but it requires two current sensors. Depending on the different weight values, a family of the splitting current single-loop control schemes with the associated filter configurations is developed in this paper, where only one current sensor is needed. As a result, high robustness, high-quality grid current and cost-efficiency can be concurrently achieved. Finally, experimental results from a 6-kW setup confirm the effectiveness and practicality of the splitting current single-loop control.

Details

Database :
OpenAIRE
Journal :
2020 22nd European Conference on Power Electronics and Applications (EPE'20 ECCE Europe)
Accession number :
edsair.doi...........c4a963353eb70a02773c397a9fa3ae00