Back to Search Start Over

Measurement of radon and thoron concentration by using LR-115 type-II plastic track detectors in the environ of Brahmaputra Valley, Assam, India

Authors :
T.D. Goswami
Subir Sarkar
P. C. Deka
T.V. Ramachandran
B. Bhattacharjee
B. K. Sarma
Source :
Radiation Measurements. 36:431-434
Publication Year :
2003
Publisher :
Elsevier BV, 2003.

Abstract

Radon/thoron and their progeny concentrations were measured in different types of dwellings at different locations around industrial areas, cities and rural areas of Brahmaputra Valley of Assam by using LR-115 (type-II) plastic detector. Radon levels of different dwellings were analysed with reference to the nature of building materials, ventilation patterns and the types of underlying soil. The results were discussed under the light of exposure limits set by ICRP. The average concentrations of indoor radon and thoron varied from 39.5 to 215.2 Bq m −3 and 12.9 to 37.6 Bq m −3 , respectively. The estimated inhalation dose due to radon, thoron and their daughter products in the study areas varied from 0.53 to 1.00 μSv h −1 .

Details

ISSN :
13504487
Volume :
36
Database :
OpenAIRE
Journal :
Radiation Measurements
Accession number :
edsair.doi...........c504c7c3c0581ea66a1161dc52691aeb
Full Text :
https://doi.org/10.1016/s1350-4487(03)00165-3