Back to Search Start Over

Ex Vivo Comparison of Efficiency, Safety, and Surgeon Satisfaction in Four Commercial Morcellators

Authors :
Eric Li
Matthew S. Lee
Lauren Folgosa Cooley
Mark A Assmus
Amy E. Krambeck
Tim Large
Source :
Journal of Endourology. 36:514-521
Publication Year :
2022
Publisher :
Mary Ann Liebert Inc, 2022.

Abstract

Introduction Holmium Laser Enucleation of the Prostate (HoLEP) is a size-independent treatment option for the management of benign prostatic hypertrophy. While advancements in laser technology have led to clinical improvements in the enucleation portion of HoLEP, the morcellation aspect of HoLEP is often the rate-limiting step. We sought to compare efficiency and surgeon satisfaction in four commercial morcellators. Methods This was an ex vivo study comparing four commercial morcellators: the Wolf Piranha, the Lumenis VersaCut, the JenaSurgical MultiCut Solo, and the Hawk Morcellator. Four surgeons with significant experience performing HoLEPs participated. Surgeons tested each device to morcellate two different prostate models 1) morcellating as much microwave-cooked chicken breast in 10 minutes and 2) timed morcellation of bull testicles. Surgeons completed subjective surveys after each morcellator trial. Objective outcomes included: morcellation efficiency (g/min morcellated) and aspiration power (time to aspirate 1 L of saline). Means of continuous variables were compared using ANOVA. Categorical variables were compared using chi-square tests. Statistical analyses were performed using SAS 9.4 (2019). Results Comparing subjective outcomes, the Piranha was chosen as the safest morcellator (p=0.0058). The least safe morcellator was thought to be the MultiCut by 75% of surgeons (p=0.046). The Piranha was chosen as the most effective morcellator by 75% of surgeons (p=0.046). Comparing objective parameters between the morcellators, the Piranha had the fastest aspiration time (43.50±10.34 s, p=0.0116). There were no significant differences in morcellation efficiency when using chicken breast (p=0.3096). However, when comparing the morcellation efficiency using bull testicles, the Piranha had the highest efficiency at 39.68±3.57 g/min (p=0.0268). Conclusion In this ex-vivo study comparing four different commercially available morcellators, the Piranha had the highest aspiration power. No significant differences were found in morcellation efficiency using microwave-cooked chicken breast. The Piranha was felt to be the safest and most effective morcellator.

Details

ISSN :
1557900X and 08927790
Volume :
36
Database :
OpenAIRE
Journal :
Journal of Endourology
Accession number :
edsair.doi...........c5c3f682512bf7cacd5321dcffe8eece