Back to Search Start Over

P-015 The zoom system demonstrates higher first pass effect and faster reperfusion as compared to a consecutive contemporaneous series of aspiration catheters: analysis from a multicenter retrospective cohort

Authors :
R DeLeacy
H Hawk
Shahid M Nimjee
Amir M. Siddiqui
Ryan T Kellogg
Maxim Mokin
Gustavo M Cortez
Eric Sauvageau
Jan Vargas
Ricardo A. Hanel
Raymond D Turner
James Milburn
Shahram Majidi
A Zakeri
A Aghaebrahmin
E Marlin
Aquilla S Turk
M Oselkin
Imran Chaudry
Source :
Oral poster abstracts.
Publication Year :
2021
Publisher :
BMJ Publishing Group Ltd., 2021.

Abstract

Background Modern aspiration catheters have revolutionized thrombectomy outcomes. The Zoom System is series of catheters, with ID’s of 0.045, 0.055, 0.071, and 0.088, that are advertised as being designed to support superior stroke thrombectomy performance. We aimed to preliminarily evaluate such claims by retrospectively assessing technical outcomes in a consecutive series of M1 ELVOs in which aspiration was the first line approach. Methods We performed a retrospective multicenter analysis of consecutive ELVO patients with M1 occlusion treated within 24 hours from the time of last known well. Patients were divided into two cohorts: those in whom the Zoom 088 or 071 was the initial technology used to attempt reperfusion and those in whom any other aspiration catheter was used for initial reperfusion attempt. The primary outcome was excellent reperfusion (TICI≥2C) on first pass. Secondary outcomes included the rate of excellent reperfusion and successful reperfusion (TICI≥2B), access to successful reperfusion time, and occurrence of downstream emboli. All data was self-adjudicated. No outside funding was provided for this analysis. Results Total of 660 patients with acute M1 occlusion who underwent thrombectomy were identified. Zoom System catheters (088 or 071) were used as primary aspiration catheter in 172 patients, while 488 patients were treated with other aspiration catheters (ranging from 064 to 074). The baseline mRS score, admission NIHSS score, the rate of intravenous thrombolytic therapy, symptom onset to hospital arrival, and use of anesthesia were not different between the cohorts. The primary outcome, first pass excellent reperfusion, was significantly higher in the Zoom System cohort (51% vs 41%, p=0.02). The rate of excellent reperfusion was significantly higher in the Zoom cohort (68% vs 59%, p=0.04), however, there was no difference in the rate of successful reperfusion (96% vs 94%, p=0.78). Access time to final reperfusion was significantly faster in the Zoom cohort (27 vs 35 minutes, p Conclusion This retrospective, multicenter, consecutive real-world experience suggests that using Zoom 088 or 071 as primary aspiration catheter may demonstrate superior technical outcomes for M1 thrombectomy. Disclosures S. Majidi: None. J. Vargas: 2; C; Cerenovus, Medtronic. 4; C; Truvic. H. Hawk: None. S. Nimjee: None. A. Zakeri: None. M. Mokin: 2; C; Medtronic, Cerenovus. R. Kellogg: None. R. DeLeacy: None. G. Cortez: None. A. Aghaebrahmin: None. E. Sauvageau: None. R. Hanel: 1; C; Microvention, Stryker. 2; C; Medtronic, Microvention, Stryker, Balt, Cerenovus, Q’Apel. A. Siddiqui: 2; C; Imperitive Care, Medtronic, Microvention, Penumbra, Q’Apel, Stryker. 4; C; Imperitive Care, Q’Apel, Truvic, RiSt. M. Oselkin: None. E. Marlin: None. A. Turk: 2; C; Impertive care, stryker, medtronic, penumbra, balt, cerenovus. 4; C; imperitive care. R. Turner: 2; C; Q’Apel, Cerenovus, Medtronic, Siemens. 4; C; Q’Apel. I. Chaudry: 2; C; Medtronic, Microvention, Q’Apel. 4; C; Q’Apel. J. Milburn: None.

Details

Database :
OpenAIRE
Journal :
Oral poster abstracts
Accession number :
edsair.doi...........cc56db5dc963ca8802222a5f9f935072
Full Text :