Back to Search
Start Over
Carbon Fiber Shear Retrofit of Forty-Two-Year-Old AASHTO I-Shaped Girders
- Source :
- Journal of Composites for Construction. 15:773-781
- Publication Year :
- 2011
- Publisher :
- American Society of Civil Engineers (ASCE), 2011.
-
Abstract
- Sixteen shear capacity tests were performed on eight decommissioned AASHTO prestressed concrete girders that had been in service for over 42 years. These bridge members presented a unique opportunity to investigate carbon fiber-reinforced polymer (CFRP) retrofit schemes to enhance the shear capacity of underreinforced girders that were nonrectangular. Four destructive tests were performed to quantify the in-service strength of the girders and the remaining 12 tests were performed on CFRP retrofitted girders. In all, five configurations of the CFRP reinforcement were evaluated. Two anchoring techniques were investigated that either involved epoxying a horizontal CFRP strip over the vertical strips or a new methodology of epoxying a CFRP laminate into a groove over the vertical strips that was cut at the web-to-flange interface. Two methodologies that predicted the shear contribution of the carbon fiber reinforcement were compared with the test results. A carbon fiber-reinforcing scheme of vertical strips a...
- Subjects :
- Materials science
business.industry
Mechanical Engineering
Anchoring
Building and Construction
Structural engineering
Fibre-reinforced plastic
law.invention
Shear (sheet metal)
Prestressed concrete
Mechanics of Materials
law
Girder
Ceramics and Composites
Shear strength
Retrofitting
Geotechnical engineering
Composite material
Reinforcement
business
Civil and Structural Engineering
Subjects
Details
- ISSN :
- 19435614 and 10900268
- Volume :
- 15
- Database :
- OpenAIRE
- Journal :
- Journal of Composites for Construction
- Accession number :
- edsair.doi...........cc832c82ef657f27f4d21fcd0e8fd509
- Full Text :
- https://doi.org/10.1061/(asce)cc.1943-5614.0000208