Back to Search Start Over

Carbon Fiber Shear Retrofit of Forty-Two-Year-Old AASHTO I-Shaped Girders

Authors :
G. Parry Osborn
David A. Petty
Marvin W. Halling
Paul J. Barr
Travis R. Brackus
Source :
Journal of Composites for Construction. 15:773-781
Publication Year :
2011
Publisher :
American Society of Civil Engineers (ASCE), 2011.

Abstract

Sixteen shear capacity tests were performed on eight decommissioned AASHTO prestressed concrete girders that had been in service for over 42 years. These bridge members presented a unique opportunity to investigate carbon fiber-reinforced polymer (CFRP) retrofit schemes to enhance the shear capacity of underreinforced girders that were nonrectangular. Four destructive tests were performed to quantify the in-service strength of the girders and the remaining 12 tests were performed on CFRP retrofitted girders. In all, five configurations of the CFRP reinforcement were evaluated. Two anchoring techniques were investigated that either involved epoxying a horizontal CFRP strip over the vertical strips or a new methodology of epoxying a CFRP laminate into a groove over the vertical strips that was cut at the web-to-flange interface. Two methodologies that predicted the shear contribution of the carbon fiber reinforcement were compared with the test results. A carbon fiber-reinforcing scheme of vertical strips a...

Details

ISSN :
19435614 and 10900268
Volume :
15
Database :
OpenAIRE
Journal :
Journal of Composites for Construction
Accession number :
edsair.doi...........cc832c82ef657f27f4d21fcd0e8fd509