Back to Search Start Over

Iodine-Filter Imaging System for Subtraction Angiography and Its Improvement by Fluorescent-Screen Harpicon Detector

Authors :
Masayoshi Akisada
Ken Ueda
Teiichi Nakajima
Yuji Itai
Keiji Umetani
Hironori Ueki
Tohoru Takeda
Izumi Anno
Source :
Medical Applications of Synchrotron Radiation ISBN: 9784431684879
Publication Year :
1998
Publisher :
Springer Japan, 1998.

Abstract

Our initial studies in animal experiments using K-edge energy subtraction transvenous coronary angiography at the Photon Factory were undertaken using an iodine filter for energy switching combined with an X-ray image intensifier. In vivo subtracted images of coronary arteries in dogs were obtained in the form of motion pictures. However, the image quality was not good for medical examinations because the contrast material was highly diluted. A new image detector with a fluorescent-screen lens-coupling approach has been developed to take high quality images. By using the new detector in place of the X-ray image intensifier, image quality has markedly increased in coronary angiography.

Details

ISBN :
978-4-431-68487-9
ISBNs :
9784431684879
Database :
OpenAIRE
Journal :
Medical Applications of Synchrotron Radiation ISBN: 9784431684879
Accession number :
edsair.doi...........ce6166515d462f779d4b47140d09f4f5
Full Text :
https://doi.org/10.1007/978-4-431-68485-5_16