Thermal comfort in naturally ventilated buildings in hot-humid area of China

Authors :
Jinyong Wang
Qinglin Meng
Yufeng Zhang
Jun Zhang
Huimei Chen
Source :
Building and Environment. 45:2562-2570
Publication Year :
2010
Publisher :
Elsevier BV, 2010.

Abstract

Human responses to thermal environments in naturally ventilated (NV) buildings in hot-humid area of China were systematically investigated in the present study. Thirty local inhabitants long-time living in NV buildings participated in the study and reported their thermal sensations and perceptions and adaptive behaviors while all physical and personal variables were collected. Based on a year-long survey, a close match of indoor physical variables and occupants’ clothing insulation with outdoor climate was found as an important feature of NV buildings. Integrated indices can capture more thermal contexts in the NV buildings in hot-humid area of China than simple indices. Thermal sensation was found to be a good linear function of SET* with the thermal neutrality of 25.4 °C and the 90% (80%) acceptable range of 23.5–27.4 °C (22.1–28.7 °C) in SET*. The adaptive evidences were obtained for clothing adjustment, window opening and using fan respectively and the modified PMV model was validated to be applicable in NV buildings in hot-humid area of China with an expectancy factor of 0.822. Comparisons with other field studies indicate that people can develop various human-environment relationships through thermal adaptation to local climate, resulting in different thermal neutral temperatures in various climates. The subjects in hot-humid area of China are more acclimated and tolerable with hot and humid environments and more uncomfortable and intolerable with cold environments while compared with those in temperate climates.

Details

ISSN :
03601323
Volume :
45
Database :
OpenAIRE
Journal :
Building and Environment
Accession number :
edsair.doi...........cfdbaefdfb86f7ec7c572615114bfefe