Back to Search Start Over

Potential diagnostic value of 131 I-MIBG myocardial scintigraphy in discrimination between Alzheimer disease and dementia with Lewy bodies

Potential diagnostic value of 131 I-MIBG myocardial scintigraphy in discrimination between Alzheimer disease and dementia with Lewy bodies

Authors :
Maryam Naseri
Mohsen Afarideh
Vajiheh Aghamollaii
Mehrshad Abbasi
Abbas Tafakhori
Mona Ahmadi
Morsaleh Ganji
Nafise Ghalandari
Saeed Farzanefar
Sogol Loloee
Source :
Clinical Neurology and Neurosurgery. 163:163-166
Publication Year :
2017
Publisher :
Elsevier BV, 2017.

Abstract

Objectives Clinical difficulty to discriminate between the Alzheimer disease (AD) and dementia with Lewy bodies (DLB) has led researchers to focus on highly sensitive functional imaging modalities. The aim of the present study was to assess 131I-MIBG cardiac imaging to distinguish between AD and DLB. Patients and methods Seventeen patients who were known cases of dementia underwent 131I-MIBG myocardial scintigraphy to differentiate AD from DLB. Planar and 131I-MIBG SPECT were obtained 2 h after the injection of 1 mCi 131I-MIBG on a dual head gamma camera. The visual assessment of the heart uptake compared with lungs and the quantification based on the heart to mediastinal ratio (HMR) were done. The cardiac receiver operating characteristic (ROC) curve was designed for the optimal HMR cut-off values to predict the diagnoses of the patients. The diagnoses were clinically confirmed during the follow up of 14 ± 8.2 months. Results Out of 17 patients (13 males; 76.5%), 10 patients had AD (7 males; 70%) and 7 patients had DLB (6 males; 85%). The pooled HMR was 1.74 ± 0.33 in the study population; with 1.95 ± 0.22 in the AD group and 1.43 ± 0.20 in the DLB group to demonstrate significantly different HMR scores between patients with AD and DLB (p value = 0.001). The visual interpretation was positive in 10 patients (accuracy of 88.2%). The shortest distance on the ROC curve to the optimal value corresponding to HMR = 1.57 identified 10 patients with a high HMR (positive cardiac uptake) and 7 patients with a low HMR (negative cardiac uptake), the accuracy calculated at 88.2%. Conclusion 131I-MIBG myocardial scintigraphy is a potential alternative diagnostic modality for discrimination between AD and DLB when 123I is not available.

Details

ISSN :
03038467
Volume :
163
Database :
OpenAIRE
Journal :
Clinical Neurology and Neurosurgery
Accession number :
edsair.doi...........d67110417d7f8bbbad52ddfc4064aa61
Full Text :
https://doi.org/10.1016/j.clineuro.2017.10.024