Pohang Accelerator Laboratory (PAL) is developing a 14 cm period wiggler (MPW14) for high flux material science(HFMS) beamline. The MPW14 is a hybrid type device achieving higher peak flux density. PLS MPW14 features period of 14cm, minimum gap of 14mm, 24 full field poles, maximum flux density of 2.02 Tesla, and the total magnetic structure length of 2056mm. The peak flux density is higher compared to the other wigglers of similar pole gap and period. The high peak flux density has been achieved by using advanced new magnetic materials and optimized magnetic geometry. The magnetic performance of the MPW14 is measured using a conventional hall probe scanning system and flipping coil system. The newly developed angularly resolved flipping coil measurement system is very precise and fast. Due to its angular resolving feature, all higher order multipole contents of the MPW14 could be measured. In this article, all the developments efforts for the PLS MPW14 wiggler and the efforts for the angularly resolving flipping coil measurement system are described.