Back to Search Start Over

The Thermal Conductance Estimation of Uncooled Microbolometer

Authors :
Hong Xi Zhou
Chao Chen
Ya Dong Jiang
Source :
Key Engineering Materials. :477-480
Publication Year :
2012
Publisher :
Trans Tech Publications, Ltd., 2012.

Abstract

Thermal conductance of microbolometer has a directly impact on Noise Equivalent Temperature Difference (NETD) and thermal time constant which are the key indicators of uncooled IR detector. It is of great significance to calculate and evaluate thermal conductance. A calculate approach of thermal conductance for uncooled microbolometer detectors is introduced in this paper. Accurate three-dimensional modeling of microbolometer is found by using MEMS analysis software Intellisuite. Dynamic thermal analysis of this model is solved and then thermal time constant can be read from thermal time curve of the analysis mentioned above. Combined with the calculation of thermal capacitance, more precisely thermal conductance value can be reached which is more accurate than theoretical calculations result and meaningful for design and fabrication of the device.

Details

ISSN :
16629795
Database :
OpenAIRE
Journal :
Key Engineering Materials
Accession number :
edsair.doi...........d93ad4dcebdb5617d7d9d188671b0670
Full Text :
https://doi.org/10.4028/www.scientific.net/kem.531-532.477