Back to Search Start Over

Engineering and maintenance studies of the ITER diagnostic upper port plug

Authors :
J. Ohmori
K. Sato
Shin Kajita
Yoshinori Kusama
Takaki Hatae
K. Ebisawa
Yuzuru Neyatani
Masao Ishikawa
Takashi Kondoh
Source :
Fusion Engineering and Design. 84:1713-1715
Publication Year :
2009
Publisher :
Elsevier BV, 2009.

Abstract

Engineering analyses have been performed for the representative diagnostic upper port plug of ITER. Maintenance and integration design have been also carried out for the diagnostic components to be installed in the upper port plug. From the electromagnetic and structural analyses, it has come up an important problem to suppress the displacement of the upper port plug rather than to reduce the produced stress. Reducing the electro-magnetic (EM) force will help to decrease the severity of potential displacement. Maximum displacement of the port plug decreases with increase in the number of slits in a manner that the displacement would seem to be less than the design tolerance. A proposed low body roller and inner frame may enhance maintenance and integration. These studies and designs have established the design basis for the diagnostic upper port plug.

Details

ISSN :
09203796
Volume :
84
Database :
OpenAIRE
Journal :
Fusion Engineering and Design
Accession number :
edsair.doi...........dac977e20c3d706c9af4ba27b687eb62
Full Text :
https://doi.org/10.1016/j.fusengdes.2009.01.085