Back to Search Start Over

Calibration procedure of the ΔE − E detectors for Deuteron breakup reaction investigation at intermediate energies at nuclotron

Authors :
Alexander Isupov
Olena Mezhenska
Yuriy V. Gurchin
Marian Janek
J. T. Karachuk
J. Urban
V. P. Ladygin
A. N. Khrenov
Aleksey N. Livanov
Arkadiy A. Terekhin
S. M. Piyadin
P. K. Kurilkin
S. G. Reznikov
Source :
PROCEEDINGS OF THE 24TH INTERNATIONAL SCIENTIFIC CONFERENCE OF YOUNG SCIENTISTS AND SPECIALISTS (AYSS-2020).
Publication Year :
2021
Publisher :
AIP Publishing, 2021.

Abstract

The aim of the deuteron spin structure (DSS) experiment is to obtain polarization observables in dp elastic scattering and in dp breakup at large CMS angles (> 60°). The dp breakup reaction has been investigated by the scintillation detectors placed at the vicinity of the Internal Target Station (ITS) of Nuclotron. Calibration data have been obtained at the deuteron energy of 300 - 500 MeV. The main goal of this report is to present the calibration procedure of the ΔE - E detectors. Calibration coefficients are used to recover the deposited particle energy.

Details

ISSN :
0094243X
Database :
OpenAIRE
Journal :
PROCEEDINGS OF THE 24TH INTERNATIONAL SCIENTIFIC CONFERENCE OF YOUNG SCIENTISTS AND SPECIALISTS (AYSS-2020)
Accession number :
edsair.doi...........df54846ee1aea796cfd5ef81fefaaf68
Full Text :
https://doi.org/10.1063/5.0063374