Analysis of an offset error on a single-phase grid-connected inverter based on a proportional-resonant controller
- Source :
- 2017 IEEE Applied Power Electronics Conference and Exposition (APEC).
- Publication Year :
- 2017
- Publisher :
- IEEE, 2017.
-
Abstract
- In single-phase grid-connected inverters, an offset error in measured phase current on grid side is occurred by a current sensor and unbalanced voltage and nonlinearity characteristics of analog components in a measurement device. When current containing offset error is used for current control, it results in DC offset and the second harmonic component of fundament frequency in phase current of a grid side. The DC offset and the second harmonic component yield reduction of inverter efficiency. This paper presents an offset error compensation algorithm for grid-connected single phase inverters using a proportional resonant (PR) controller. The proposed algorithm is verified in simulation and experiment.
- Subjects :
- Engineering
Offset (computer science)
Input offset voltage
business.industry
020209 energy
020208 electrical & electronic engineering
02 engineering and technology
Grid
Nonlinear system
Control theory
0202 electrical engineering, electronic engineering, information engineering
Inverter
Current sensor
business
DC bias
Voltage
Subjects
Details
- Database :
- OpenAIRE
- Journal :
- 2017 IEEE Applied Power Electronics Conference and Exposition (APEC)
- Accession number :
- edsair.doi...........dfadf913f44ea06e9e60462e1b11e2b7
- Full Text :
- https://doi.org/10.1109/apec.2017.7931067