Back to Search Start Over

Precision equation-of-state measurements on National Ignition Facility ablator materials from 1 to 12 Mbar using laser-driven shock waves

Authors :
T. R. Boehly
Gilbert Collins
D. D. Meyerhofer
M. A. Barrios
Jon Eggert
Damien Hicks
Dayne Fratanduono
Source :
Journal of Applied Physics. 111:093515
Publication Year :
2012
Publisher :
AIP Publishing, 2012.

Abstract

A large uncertainty in the design of ignition capsules for use in the National Ignition Campaign (NIC) is the ablator equation of state. In this article, we report equation-of-state measurements for two candidate NIC ablator materials, glow-discharge polymer (GDP), and germanium-doped GDP. These materials were driven to pressures of 1 to 12 Mbar using laser-driven shock waves. Hugoniot measurements were obtained using the impedance matching technique with an α-quartz standard. This article presents the first kinematic measurements in the high-pressure fluid regime for these materials, which show to be in close agreement with Livermore equation-of-state model predictions.

Details

ISSN :
10897550 and 00218979
Volume :
111
Database :
OpenAIRE
Journal :
Journal of Applied Physics
Accession number :
edsair.doi...........e0139bac99304f3abf217f2dbea56ab7
Full Text :
https://doi.org/10.1063/1.4712050