Back to Search Start Over

Fluid Finite Element Analysis for Hot-Air Valve Duct

Authors :
H. Yu
Y. Yao
Source :
Advanced Engineering Forum. :995-998
Publication Year :
2011
Publisher :
Trans Tech Publications, Ltd., 2011.

Abstract

Hot-air valve can be easily ineffective during the operation due to the bad influence of the eddy heat on the bottom outer-edge of the valve plate. COSMOSFloworks software was used to analyze the flow field of DN1800 hot-air valve duct in a certain domestic company, by adopting the classical formula of heat transfer theory’s convective recuperative system as reference. The analysis results showed that during the beginning opening of hot-air valve duct, the bottom outer-edge of valve plate receive the influence that the hot-air enforce convection heat exchanger, while during the late opening of hot-air valve duct , the bottom outer-edge of valve plate receive the influence of eddy heat exchange. Based on this analysis , the paper suggests the measures which bring down the temperature of outer-edge of valve plate .

Details

ISSN :
2234991X
Database :
OpenAIRE
Journal :
Advanced Engineering Forum
Accession number :
edsair.doi...........e53000123a531099e74d443f00dfebea