Clinical Validation of a Peritoneal Dialysis Prescription Model in the PatientOnLine Software
- Source :
- Artificial Organs. 40:144-152
- Publication Year :
- 2015
- Publisher :
- Wiley, 2015.
-
Abstract
- Peritoneal transport characteristics and residual renal function require regular control and subsequent adjustment of the peritoneal dialysis (PD) prescription. Prescription models shall facilitate the prediction of the outcome of such adaptations for a given patient. In the present study, the prescription model implemented in the PatientOnLine software was validated in patients requiring a prescription change. This multicenter, international prospective cohort study with the aim to validate a PD prescription model included patients treated with continuous ambulatory peritoneal dialysis. Patients were examined with the peritoneal function test (PFT) to determine the outcome of their current prescription and the necessity for a prescription change. For these patients, a new prescription was modeled using the PatientOnLine software (Fresenius Medical Care, Bad Homburg, Germany). Two to four weeks after implementation of the new PD regimen, a second PFT was performed. The validation of the prescription model included 54 patients. Predicted and measured peritoneal Kt/V were 1.52 ± 0.31 and 1.66 ± 0.35, and total (peritoneal + renal) Kt/V values were 1.96 ± 0.48 and 2.06 ± 0.44, respectively. Predicted and measured peritoneal creatinine clearances were 42.9 ± 8.6 and 43.0 ± 8.8 L/1.73 m2/week and total creatinine clearances were 65.3 ± 26.0 and 63.3 ± 21.8 L/1.73 m2/week, respectively. The analysis revealed a Pearson's correlation coefficient for peritoneal Kt/V of 0.911 and Lin's concordance coefficient of 0.829. The value of both coefficients was 0.853 for peritoneal creatinine clearance. Predicted and measured daily net ultrafiltration was 0.77 ± 0.49 and 1.16 ± 0.63 L/24 h, respectively. Pearson's correlation and Lin's concordance coefficient were 0.518 and 0.402, respectively. Predicted and measured peritoneal glucose absorption was 125.8 ± 38.8 and 79.9 ± 30.7 g/24 h, respectively, and Pearson's correlation and Lin's concordance coefficient were 0.914 and 0.477, respectively. With good predictability of peritoneal Kt/V and creatinine clearance, the present model provides support for individual dialysis prescription in clinical practice. Peritoneal glucose absorption and ultrafiltration are less predictable and are likely to be influenced by additional clinical factors to be taken into consideration.
- Subjects :
- medicine.medical_specialty
medicine.medical_treatment
Concordance
030232 urology & nephrology
Biomedical Engineering
Urology
Medicine (miscellaneous)
Renal function
Bioengineering
Peritoneal dialysis
Biomaterials
03 medical and health sciences
chemistry.chemical_compound
0302 clinical medicine
Medicine
030212 general & internal medicine
Medical prescription
Prospective cohort study
Dialysis
Creatinine
business.industry
Continuous ambulatory peritoneal dialysis
General Medicine
Surgery
chemistry
business
Subjects
Details
- ISSN :
- 0160564X
- Volume :
- 40
- Database :
- OpenAIRE
- Journal :
- Artificial Organs
- Accession number :
- edsair.doi...........e5324a0192114151c4d34efd93dd6387
- Full Text :
- https://doi.org/10.1111/aor.12526