Detektion von Lungenrundherden mit der Magnetresonanztomographie in Atemanhaltetechnik im Vergleich zur Spiral-Computertomographie

Authors :
J. Vollmar
Claus D. Claussen
B. Erdtmann
Fritz Schick
M. D. Seemann
Jürgen F. Schäfer
P. Kamm
Source :
RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren. 177:41-49
Publication Year :
2005
Publisher :
Georg Thieme Verlag KG, 2005.

Abstract

PURPOSE Evaluation of sensitivity and false positive findings of two fast MRI sequences for the detection of pulmonary nodules in comparison with spiral CT by two independent observers. MATERIALS AND METHODS All 30 enrolled patients had a spiral CT or MSCT as base line study. MRI was performed with a 1.5 T MR scanner (Sonata, Siemens) using a transverse 3D gradient echo sequence (3D-GRE: TR/TE/flip = 2.9 ms/1.1 ms/5 degrees ) and a half-Fourier single-shot fast spin-echo sequence (HASTE: TR/TE/flip = 800/25/150 degrees ) acquired in three planes. A separate analysis for both sequences was carried out prospectively by two independent readers (A and B) with different experience regarding pulmonary MRI. Additionally, a retrospective reading with knowledge of the CT scans was done. Results were calculated for all lesions and for lesions larger than 4 mm. RESULTS The sensitivities were 73 %, 70 % and 84 % for the 3D-GRE sequence (reader A, reader B, retrospective reading) and 65 %, 68 % and 81 % for the HASTE sequence. For lesions larger than 4 mm, the sensitivities were 93 %, 89 %, 96 % for the 3D-GRE sequence and 85 %, 85 %, 96 % for the HASTE sequence. The rate of false positive findings depended on the reader's experience, but was generally lower for the 3D-GRE sequence with 2 and 16 (reader A and B) false positive nodules compared to 4 and 40 false positive findings for the HASTE sequence. The 3D-GRE sequence was more accurate for both readers (reader A: p = 0.08, reader B: p = 0.00003). CONCLUSION The sensitivity of MRI for the detection of lung nodules was only acceptable for lesions larger than 4 mm. The 3D-GRE sequence is superior to the HASTE sequence due to the reduced amount of false positive findings with comparable sensitivity.

Details

ISSN :
14389010 and 14389029
Volume :
177
Database :
OpenAIRE
Journal :
RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
Accession number :
edsair.doi...........e8a4e9c9a24f646a74366ae6770c68c6
Full Text :
https://doi.org/10.1055/s-2004-813857