Back to Search
Start Over
NO2column amounts from ground-based Pandora and MFDOAS spectrometers using the direct-sun DOAS technique: Intercomparisons and application to OMI validation
- Source :
- Journal of Geophysical Research. 114
- Publication Year :
- 2009
- Publisher :
- American Geophysical Union (AGU), 2009.
-
Abstract
- [1] Vertical column amounts of nitrogen dioxide, C(NO 2 ), are derived from ground-based direct solar irradiance measurements using two new and independently developed spectrometer systems, Pandora (Goddard Space Flight Center) and MFDOAS (Washington State University). We discuss the advantages of C(NO 2 ) retrievals based on Direct Sun - Differential Optical Absorption Spectroscopy (DS-DOAS). The C(NO 2 ) data are presented from field campaigns using Pandora at Aristotle University (AUTH), Thessaloniki, Greece; a second field campaign involving both new instruments at Goddard Space Flight Center (GSFC), Greenbelt, Maryland; a Pandora time series from December 2006 to October 2008 at GSFC; and a MFDOAS time series for spring 2008 at Pacific Northwest National Laboratory (PNNL), Richland, Washington. Pandora and MFDOAS were compared at GFSC and found to closely agree, with both instruments having a clear-sky precision of 0.01 DU (1 DU = 2.67 × 10 16 molecules/cm 2 ) and a nominal accuracy of 0.1 DU. The high precision is obtained from careful laboratory characterization of the spectrometers (temperature sensitivity, slit function, pixel to pixel radiometric calibration, and wavelength calibration), and from sufficient measurement averaging to reduce instrument noise. The accuracy achieved depends on laboratory-measured absorption cross sections and on spectrometer laboratory and field calibration techniques used at each measurement site. The 0.01 DU precision is sufficient to track minute-by-minute changes in C(NO 2 ) throughout each day with typical daytime values ranging from 0.2 to 2 DU. The MFDOAS instrument has better noise characteristics for a single measurement, which permits MFDOAS to operate at higher time resolution than Pandora for the same precision. Because Pandora and MFDOAS direct-sun measurements can be made in the presence of light to moderate clouds, but with reduced precision (~0.2 DU for moderate cloud cover), a nearly continuous record can be obtained, which is important when matching OMI overpass times for satellite data validation. Comparisons between Pandora and MFDOAS with OMI are discussed for the moderately polluted GSFC site, between Pandora and OMI at the AUTH site, and between MFDOAS and OMI at the PNNL site. Validation of OMI measured C(NO 2 ) is essential for the scientific use of the satellite data for air quality, for atmospheric photolysis and chemistry, and for retrieval of other quantities (e.g., accurate atmospheric correction for satellite estimates of ocean reflectance and bio-optical properties). Changes in the diurnal variability of C(NO 2 ) with season and day of the week are presented based on the 2-year time series at GSFC measured by the Pandora instrument.
- Subjects :
- Atmospheric Science
Ecology
Meteorology
Spectrometer
Differential optical absorption spectroscopy
Instrumentation
Atmospheric correction
Paleontology
Soil Science
Forestry
Aquatic Science
Oceanography
Solar irradiance
Geophysics
Space and Planetary Science
Geochemistry and Petrology
Earth and Planetary Sciences (miscellaneous)
Calibration
Environmental science
Satellite
Radiometric calibration
Earth-Surface Processes
Water Science and Technology
Remote sensing
Subjects
Details
- ISSN :
- 01480227
- Volume :
- 114
- Database :
- OpenAIRE
- Journal :
- Journal of Geophysical Research
- Accession number :
- edsair.doi...........eeb6b04092e966aafae70e72a507efda
- Full Text :
- https://doi.org/10.1029/2009jd011848