Abstract
- The effects of nuclear radiations on conventional thermocouples (type K, C and N) mainly used in irradiation experiments may create significant drifts of the signals. In order to solve these difficulties, the Commissariat a l'Energie Atomique has started to develop and qualify in laboratory conditions a miniature device, which combines a noise thermometer and thermocouples, for a future application in a research reactor. In this paper, a particular approach of a combined noise thermometer-thermocouples is described. Present measurements, based on a correlation and comparison method, are realized in laboratory at 300°C which represents the mean temperature in materials irradiation experiments. Referred measurement uncertainties are lower than ±1.5°C corresponding to the accuracy tolerance of conventional thermocouples at this temperature.
- Subjects :
- Nuclear and High Energy Physics
Materials science
Noise measurement
Nuclear engineering
Noise (electronics)
Temperature measurement
law.invention
Nuclear Energy and Engineering
Thermocouple
law
Thermometer
Measuring instrument
Electronic engineering
Research reactor
Electrical and Electronic Engineering
Resistor
Subjects
Details
- ISSN :
- 15581578 and 00189499
- Volume :
- 58
- Database :
- OpenAIRE
- Journal :
- IEEE Transactions on Nuclear Science
- Accession number :
- edsair.doi...........f2497f118e57776d205a77fea08c7abe
- Full Text :
- https://doi.org/10.1109/tns.2010.2096233