水汽扫描探测激光雷达系统常数的简易定标方法

Authors :
Shaolin Wang
Yin-chao Zhang
Wei Li
Pei-tao Zhao
Shunxing Hu
Kaifa Cao
Huanling Hu
Source :
Chinese Optics Letters. 8:541
Publication Year :
2010
Publisher :
Shanghai Institute of Optics and Fine Mechanics, 2010.

Abstract

Lower tropospheric water vapor measurements are performed at nighttime using the mobile atmosphere monitoring lidar-2 (AML-2) which is operated by the Anhui Institute of Optics and Fine Mechanics. In this lidar system, a 354.7-nm light from a Nd:YAG laser is used as stimulating source, whose Raman shifted center wavelengths are at 386.7 and 407.5 nm for nitrogen and water vapor, respectively. We present a novel and convenient method for determining the Raman lidar calibration constant according to the scanning performance of this lidar. We are likewise able to realize the measurement of water vapor profile in the low troposphere. The error induced by the uncertainty of calibrated constants is within 7% for the Raman lidar system. Experimental results from two months of study indicate that the method of calibrating the lidar system constant is feasible, and the Raman lidar performance is stable and reliable.