Back to Search
Start Over
Pulmonary MRI of neonates in the intensive care unit using 3D ultrashort echo time and a small footprint MRI system
- Source :
- Journal of Magnetic Resonance Imaging. 45:463-471
- Publication Year :
- 2016
- Publisher :
- Wiley, 2016.
-
Abstract
- PURPOSE To determine the feasibility of pulmonary magnetic resonance imaging (MRI) of neonatal lung structures enabled by combining two novel technologies: first, a 3D radial ultrashort echo time (UTE) pulse sequence capable of high spatial resolution full-chest imaging in nonsedated quiet-breathing neonates; and second, a unique, small-footprint 1.5T MRI scanner design adapted for neonatal imaging and installed within the neonatal intensive care unit (NICU). MATERIALS AND METHODS Ten patients underwent MRI within the NICU, in accordance with an approved Institutional Review Board protocol. Five had clinical diagnoses of bronchopulmonary dysplasia (BPD), and five had putatively normal lung function. Pulmonary imaging was performed at 1.5T using 3D radial UTE and standard 3D fast gradient recalled echo (FGRE). Diagnostic quality, presence of motion artifacts, and apparent severity of lung pathology were evaluated by two radiologists. Quantitative metrics were additionally used to evaluate lung parenchymal signal. RESULTS UTE images showed significantly higher signal in lung parenchyma (P < 0.0001) and fewer apparent motion artifacts compared to FGRE (P = 0.046). Pulmonary pathology was more severe in patients diagnosed with BPD relative to controls (P = 0.001). Infants diagnosed with BPD also had significantly higher signal in lung parenchyma, measured using UTE, relative to controls (P = 0.002). CONCLUSION These results demonstrate the technical feasibility of pulmonary MRI in free-breathing, nonsedated infants in the NICU at high, isotropic resolutions approaching that achievable with computed tomography (CT). There is potential for pulmonary MRI to play a role in improving how clinicians understand and manage care of neonatal and pediatric pulmonary diseases. J. Magn. Reson. Imaging 2016. LEVEL OF EVIDENCE 2 J. Magn. Reson. Imaging 2017;45:463-471.
- Subjects :
- medicine.medical_specialty
Lung
Neonatal intensive care unit
medicine.diagnostic_test
business.industry
Magnetic resonance imaging
medicine.disease
Intensive care unit
030218 nuclear medicine & medical imaging
law.invention
03 medical and health sciences
0302 clinical medicine
medicine.anatomical_structure
030228 respiratory system
Bronchopulmonary dysplasia
law
medicine
Radiology, Nuclear Medicine and imaging
Ultrashort echo time
Pulmonary pathology
Radiology
Medical diagnosis
business
Subjects
Details
- ISSN :
- 10531807
- Volume :
- 45
- Database :
- OpenAIRE
- Journal :
- Journal of Magnetic Resonance Imaging
- Accession number :
- edsair.doi...........f37c7d5660f761ef47e337aefcd09b55
- Full Text :
- https://doi.org/10.1002/jmri.25394