Back to Search Start Over

An ASIC readout system for PAD detectors

Authors :
M.J. Lovell
P. Murray
M.J. French
Source :
IEEE Conference on Nuclear Science Symposium and Medical Imaging.
Publication Year :
2003
Publisher :
IEEE, 2003.

Abstract

A full custom chipset has been designed at the Rutherford Appleton Laboratory for the readout of cathode pads in a RICH detector. The circuits form readout modules that are connected in an array that may be extended to instrument detectors of any size. Each read-out module contains three ASICs (application-specific integrated circuits), two eight-channel bipolar preamplifier and discriminator chips, and one 16-channel digital data processing chip. Each module thus processes 16 channels of detector signal. A brief description of each chip is included together with a summary of the readout architecture and test results. >

Details

Database :
OpenAIRE
Journal :
IEEE Conference on Nuclear Science Symposium and Medical Imaging
Accession number :
edsair.doi...........f3e32536e4ead98de37af8945c90fd0d
Full Text :
https://doi.org/10.1109/nssmic.1992.301265