Back to Search Start Over

Hochaufgelöste quantitative MR-tomografische Bestimmung der subendo- und subepimyokardialen Perfusion unter Stress und in Ruhe

Authors :
Herbert Köstler
K del Savio
Christian Ritter
Dietbert Hahn
A Brackertz
Meinrad Beer
Source :
RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren. 179:945-952
Publication Year :
2007
Publisher :
Georg Thieme Verlag KG, 2007.

Abstract

Purpose MR stress perfusion imaging of the heart allows the quantification of myocardial perfusion and the evaluation of myocardial perfusion reserve (MPR) and the ratio of subendocardial to subepicardial perfusion at rest and under adenosine stress. The aim of this study was to evaluate a high-resolution GRAPPA sequence for quantitative MR first pass perfusion imaging in healthy volunteers. Materials and methods First pass stress and rest perfusion studies were performed on 10 healthy volunteers using a 1.5 T MR scanner with a multislice SR-TrueFISP first pass perfusion sequence with a GRAPPA algorithm (acceleration factor 3) in prebolus technique and an image resolution of 1.8 x 1.8 mm. For the comparison group, we examined 12 different healthy volunteers with a standard first pass perfusion SR-TrueFISP sequence using a resolution of 2.7 x 3.3 mm. Myocardial contours were manually delineated followed by an automatic division of the myocardium into two rings with an equal thickness for the subendo- and subepicardial layer. Eight sectors per slice were evaluated using contamination and baseline correction. Results Using the GRAPPA sequence, the ratio of subendo- to subepimyocardial perfusion was 1.18 +/- 0.32 for the examination at rest. Under pharmacologically induced stress, the ratio was 1.08 +/- 0.27. For the standard sequence the ratio was 1.15 +/- 0.28 at rest and 1.11 +/- 0.33 under stress. For the high resolution sequence higher mean values for the subendo- to subepimyocardial ratio were obtained with comparable standard deviations. The difference between the sequences was not significant. Conclusion The evaluation of subendomyocardial and subepimyocardial perfusion is feasible with a high-resolution first pass perfusion sequence. The use of a higher resolution to avoid systematic error leads to increased image noise. However, no relevant reduction in the quantitative perfusion values under stress and at rest was able to be depicted.

Details

ISSN :
14389010 and 14389029
Volume :
179
Database :
OpenAIRE
Journal :
RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
Accession number :
edsair.doi...........f6551a0b72bd9e1252728e9cf6283bf5
Full Text :
https://doi.org/10.1055/s-2007-963350